![]() Enter M503 again to verify the new values are saved. So we started with M301 P22.20 I1.08 D114.00 and our new values are Kp 40.63 Ki 5.98 Kd 69.06 This makes the new code to enter in the command line: M301 P40.63 I5.98 D69.06 One received then enter M500 to save the new values to the eeprom. More information about PID Tuning can be found on the RepRap wiki. These should be the same as the values we just saved. Run the M304 P824.78 I154.89 D1097.99 command to add the new values Run M500 to save the values. The previous values were so we need to adapt the command with the new values and save them. ![]() This command initiates a process of heating and cooling to determine the proper PID values for the specified hotend or the heated bed. Printing the planet, one layer at a time.